sql

FLOW METER CALIBRATION SYSTEM

Rp. CALL
Last Updated
02 May 2023
Country Origin
India
Minimum Order
1 UNIT
Category
Calibrator

MOBILE FLOW METER CALIBRATION SYSTEM TROLLEY MOUNTED WITH COMPARISON METHOD



  • MOBI-FMCS 1580 Mobile Flow Meter Calibration System is designed for calibrating flow meters of sizes from DN 15 to DN 80 through Comparison Method.

  • The System has Two Trolley Type Section (One with Reservoir & Pumps Section and the other Test Rig with Master Electro Magnetic Flow Meters) & this Calibration system is manually operated.
  • Test Rig has Single Test Line to accommodate / mount Unit under Test. Only one No. of Flow meter can be calibrated at a time.
  • Calibrated & Certified Electromagnetic Flow meters will be used as the Standard / Reference Masters against which the Flow Meter under Test will be calibrated. To effectively cover the Flow Rates (from minimum 5 LPM to maximum 1500 LPM) in Meter Sizes (DN 15 to DN 80), Two Nos. of Electromagnetic Flow meter (DN 15 & DN65) shall be used as “Standard”.

Calibrated Accuracy of the Electromagnetic Flow meter shall be ± 0.2% of Reading.

  • Pressure Measurement devices will be provided at both Upstream / Downstream of the test rig to measure the Inlet / Outlet Pressure of water.
  • Temperature measurement devices will be provided to measure the Temperature of Water.
  • Flow Control through Manual Throttling Valves & VFD connected to the Pump.
  • Best “Accuracy” of ‘Unit Under Test’ that can be Tested / Calibrated (Recommended): ± 0.5%.

TECHNICAL DESCRIPTION:

System Operation

Manual

Meter Sizes

DN 15 to DN 80

Number of meter can be calibrated at a time

One

Flow Rate

Minimum 5 LPM & Maximum 1500 LPM

Calibration Media

Water (Correction factors for other Types of liquids through our “Flocal” software)

Power Supply

3 Phase, Standard Voltage 380 to 415V AC, 50Hz, 25 Kw Single Phase – 230V AC/50 Hz

Overall dimensions

Trolley 1 – Reservoir with Pumps section: Approx. 1000 x 1000 x 1000 mm (LBH) Trolley 2 – Test Rig With Master Flow Meter: Approx. 1000 x 1000 x 1000 mm (LBH)

Construction materials

Powder coated mild steel for test bench frame. All other wetted parts shall be of Stainless Steel.

Control panel

To mount Temperature Indicator, Start / Stop Button, Emergency – ON / OFF, Pump – ON / OFF, VFD Control Knob, will be provide

Commputer System

Software - to handle / operate the process, display the parameters like flow rate / Total Volume, Temperature & Pressure readings.

  • UUT’s – Flow Reading, Model/Serial No and Pressure & Temperature Readings to be keyed by manually.
  • The Software “Flocal” will generate the Calibration Report.

LAPTOP & Printer – Your/Customer Scope.

RESERVOIR WITH PUMPS SECTION – Trolley 1

Storage Tank / Water Reservoir (SS)

Mild Steel (Powder Coated) Inside: Epoxy Coated Capacity : 1000 Liters

Water supply

Through Pump

Low:

5 m3/hr. @ 3 bar

0.75 Kw / 3 Phase / 50 Hz

High:

120 m3/hr. @ 3 bar

15 Kw / 3 Phase / 50 Hz

Flow Control

Manual Throttling Valves & VFD connected to the Pump

TEST RIG WITH MASTER FLOW METER – Trolley 2

Calibration Master

2 Nos. Of Calibrated & Certified Electromagnetic Flow Meters of Size

DN 15

Flow Range: 2 LPM to 100 LPM Calibrated Accuracy: ± 0.2% of Reading.

DN 65

Flow Range: 40 LPM to 2000 LPM Calibrated Accuracy: ± 0.2% of Reading.

Number of Test Line

Single

Meter Clamping, Meter Mounting

Manual Clamping

Pressure Measurement

Pressure Gauges (Inlet / Outlet)

Range: 0 to 10 bar Dial Size: 100 mm, Accuracy: 1.6% FS

Temperature Measurement

RTD with Digital Indicator

Range: 0 to 100°C; Display: 3 ½ Digit

Show More

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Request a Quote
Produk Siap di Pesan
Rp 0
1